FDC-2002T Protection level 6 Online UPS

  • Capacity: 2000VA/1600W
  • Topology: Online Double Conversion
  • Waveform: Pure sine wave
  • Voltage: 220V
  • Type of input: NEMA 5-15P
  • Types of outputs: 4 x NEMA 5-20R
  • Communication: USB / SNMP / RS-232
  • Visual indicator: LCD status screen
  • Management software: Forza Tracker
  • Warranty: 3 years (2 years on batteries)

Communication Port

Enhanced communication and control capabilities Enables the automatic shutdown function, safely powering down connected computers

Status LCD

Takes the guesswork out of UPS management Simplified monitoring and management in real time

Battery Self-Test

Keeping your UPS healthy year-round Designed to reveal any weakness in order to prevent major failures

Automatic Voltage Regulation

Complete AVR protection against voltage irregularities Essential in areas where voltage fluctuations occur frequently, providing clean and stable power

Thermofuse Protection

Increased reliability and peace of mind Power disconnection function when transformer temperatures become too high

Cold Start Function

Ultimate power reserve for less downtime Instantly start the UPS in battery mode without AC utility power

PRODUCT SPECIFICATIONS

FDC-2002T | Online UPS

Solution type
  • Government
  • Corporate
  • Education
Replacement battery
FUB-1290
Number of batteries: 4
Order here
Applications
  • Workstations
  • Medium servers
  • Networking equipment
 
  • Graphic workstations
  • Multifunction printer
  • Copiers

The EOS series of UPS units have been conceived fortrue on-line operation with pure sine wave output andzero transfer time. An innovative and revolutionarydesign makes this one of the smallest, yet most powerfulunits in the market with the highest level of protectionagainst mission critical equipment. Double conversiontopology ensures that all connected equipment areisolated from any potential power problems caused bythe incoming AC source. Featuring a 1000VA and2000VA capacity configuration along with a convenientto read LCD, the EOS series stands out as a reliable andhighly efficient line of on-line UPS units backed throughease of use and quick relay of system vitals.

FDC-2002T | Online UPS

  • Capacity: 2000VA/1600W
  • Topology: Online Double Conversion
  • Waveform: Pure sine wave
  • Voltage: 220V
  • Type of input: NEMA 5-15P
  • Types of outputs: 4 x NEMA 5-20R
  • Communication: USB / SNMP / RS-232
  • Visual indicator: LCD status screen
  • Management software: Forza Tracker
  • Warranty: 3 years (2 years on batteries)

FDC-2002T | Online UPS

Online double conversion topology
Online UPS with true double-conversion technology offer the highest level of protection suitable for mission critical equipment by isolating the connected loads from raw utility power. This system works by converting power from AC to DC and then back to AC thanks to its two stage inverter and rectifier design.
Battery backup
Supplies battery-derived backup power during blackouts, preventing loss of critical information and minimizing equipment stress caused by a hard shutdown. Delivers reserved energy long enough for equipment to properly shut down.
Automatic voltage regulation (AVR)
Provides clean and stable AC power by automatically increasing low voltages during brownouts and decreasing overvoltages when irregularities are present on the main utility line.
Automatic shut-off
Guard your equipment against potentially damaging power fluctuations and other irregularities in the electrical supply by shutting down the power when voltage levels become too low or too high.
Surge protection, overload protection, electric discharge and voltage protection
Diverts excess voltage away from connected equipment during power surges or power spikes without reducing battery power used to run primary critical equipment. Extends battery life by preventing system overloads and controlling charging currents.
MOV Technology
Metal Oxide Varistor (MOV) technology helps absorb and it redirects transient energy preventing stray electricity from reaching protected equipment.
Thermofuse protection
Instantly disconnects the power when internal temperatures become dangerously high.
Power filters
Reduces electromagnetic interference (EMI) and radio frequency interference (RFI) to block unwanted noise, providing clean and distortion-free electricity to all power outlets.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery self-test
Ensures early failure notifications of bad or old batteries for immediate replacement, preventing any unexpected and unforeseen backup power issues.
Active power factor correction
Counteracts harmonic distortion by modifying the power factor of the UPS in order to maximize the use of the electrical power from the main utility line.
Audible alarm
Provides audible notification of changing utility power and UPS power conditions for when the UPS is installed in hard to reach places or not easily seen by the user.
Cold start function
Reserves temporary battery power used to start up the UPS in battery mode when the utility power is out. Restores immediate emergency power to the load after installing new batteries.
Status LCD
Displays live status of the UPS with detailed information on battery and power conditions, alerting users to potential problems before they can affect equipment and cause costly downtime.
Communication ports
USB port enables the automatic shutdown function, safely powering down connected computers so as to prevent important data loss. Remotely manage and monitor UPS operations with the included user-friendly dashboard interface.
Forza tracker management software
Allows control and monitoring of multiple UPS units through a network connection. The software also prevents data loss from power outages by safely shutting down the UPS units while allowing the immediate detection and correction of any operation issues with minimal or no delay.
Inverter and generator compatible
Engineered to properly work with frequency variations caused by emergency inverters and backup generators in areas with severe electrical fluctuations.
Ventilation system
Extraction fan helps remove excess heat from the inside housing, guaranteeing to keep components within acceptable operating temperatures.
Metal housing
Heavy-duty, impact-resistant metal construction
ECO Mode
Environmentally friendly mode which reduces energy consumption and improves overall efficiency by minimizing the waste of energy.
Intelligent card slot
Used to add an optional SNMP communication card for real-time monitoring and alerts of the UPS across a network.
3-year warranty
Forza Power Technologies offers a direct replacement program that exchanges a defective product from the original purchase date. See warranty terms for details.

You can find all documents relevant to your product here

Product information in English
Download
Product information in Spanish
Download
User manual in English
Download
User manual in Spanish
Download

FDC-2002T | Online UPS

Our Technical Support team will be happy help you with technical questions during business hours.

Email
[email protected]

Live Chat
Monday - Friday
9am — 7pm (UTC-5)
Form Online

For support Click Here

FDC-2002T | Online UPS

PEOPLE ALSO LOOKED FOR